INSTALLATION GUIDE
Multi-Loop Process Controller
53MC5000
MICRO-DCI
.
MODULAR CONTROLLER
PN24976
Rev1
Vedere la pagina 0
1 2 3 4 5 6 ... 98 99

Sommario

Pagina 1 - INSTALLATION GUIDE

INSTALLATION GUIDE Multi-Loop Process Controller53MC5000MICRO-DCI. MODULAR CONTROLLERPN24976Rev1

Pagina 2 - MicroMod Automation, Inc

53MC5 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _Dual Relay ITBNot ImplementedOne ITBTwo ITB’sThree ITB’sX123Analog I/O OptionNot ImplementedSingle Channel Analog I

Pagina 3 - Table of Contents

2.0 INSTALLATION2.1 INSPECTIONAn itemized list of all items in the shipment is attached to the shipping container. Inspect the equip-ment upon arrival

Pagina 4

where the panel offers very little support. It is recommended that the 9 inch minimum center line di-mension between horizontally mounted rows be incr

Pagina 5 - READ FIRST

FIGURE 2-1. OUTLINE DIMENSIONS AND PANEL CUT-OUT REQUIREMENTSMODULAR CONTROLLER QUICK START2-3

Pagina 6 - 1.0 INTRODUCTION

FIGURE 2-2. OUTLINE DIMENSIONS FOR ITBMODULAR CONTROLLER QUICK START2-4

Pagina 7

FIGURE 2-3. SINGLE OR MULTIPLE PANEL MOUNTINGFIGURE 2-4. INTERCASE SPACINGMODULAR CONTROLLER QUICK START2-5

Pagina 8 - 1.3 MODEL NUMBER BREAKDOWN

2.4 INTERCONNECTIONS2.4.1 PREPARATORYThe 53MC5000 can be configured as any of a variety of conventional controller types, enabling it tobe easily adap

Pagina 9

NOTEUse of a common bus bar is recommended to minimize potential voltagedifferences that may occur as the result of ground current loops, i.e.,potenti

Pagina 10

2.4.2.5 CONTACT OUTPUTSTwo discrete contact outputs (DO0 to DO1, typically one for each of two separate process measure-ment loops) are identified in

Pagina 11 - 2.0 INSTALLATION

FIGURE 2-5. STANDARD AND OPTIONAL REAR TERMINAL BOARDMODULAR CONTROLLER QUICK START2-9

Pagina 12 - 2.3.2 MOUNTING PROCEDURE

MicroMod Automation, Inc. The Company MicroMod Automation is dedicated to improving customer efficiency by providing the most ost-effective, applica

Pagina 13 - REQUIREMENTS

FIGURE 2-6. DATALINK INSTALLATION DIAGRAM FOR STANDARDREAR TERMINAL BOARDMODULAR CONTROLLER QUICK START2-10

Pagina 14

2.5 CORD SETS (OPTIONAL)2.5.1 GENERALThe 53MC5000 Cord Set receptacle and cables are an alternate method of interconnecting theController to a remotel

Pagina 15 - FIGURE 2-4. INTERCASE SPACING

FIGURE 2-7. CORD SET REAR TERMINAL BOARDMODULAR CONTROLLER QUICK START2-12

Pagina 16 - 2.4 INTERCONNECTIONS

FIGURE 2-8. CORD SET DATALINK INSTALLATION DIAGRAMMODULAR CONTROLLER QUICK START2-13

Pagina 17 - 2.4.2.4 CURRENT OUTPUT

FIGURE 2-9. CORD SET INTERCONNECTION TERMINAL BOARDMODULAR CONTROLLER QUICK START2-14

Pagina 18 - 2.4.3 FACTORY SET CALIBRATION

2.6 GROUNDINGInstallations are expected to have access to an independent, high quality, noise-free point of earthreference. The system should be conne

Pagina 19

3.0 FUNCTIONALITYThis section provides general instructions for configuring the 53MC5000 Modular Controller for op-eration, and the information neces

Pagina 20 - REAR TERMINAL BOARD

FIX 97 - Display TestFIX 97 causes a series of three test patterns to appear on the display. One pattern lights the dotsaround the outer edge of the d

Pagina 21 - 2.5 CORD SETS (OPTIONAL)

3.1 CONTROLLER FRONT PANEL3.1.1 DISPLAYThe Modular Controller contains a high visibility dot matrix display. It is possible to configure staticand/or

Pagina 22

FIGURE 3-1. MODULAR CONTROLLER FRONT PANELNote: EMODE = Engineering ModeMODULAR CONTROLLER QUICK START3-4

Pagina 23

Table of Contents1.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11.1 DESCRIPT

Pagina 24

Figure 3-2. Engineer Mode Command Overview *See 53MC5000 Customization Guide ** If configuredBlocks shown shaded only appear when using the Hi-Re

Pagina 25 - 2.6 GROUNDING

3.2 ENGINEER MODE OVERLAYSThe Engineer Mode Overlays are used to view (Display) or make necessary changes (Config-ure) to the controller database par

Pagina 26 - 3.0 FUNCTIONALITY

•The screen should now appear as shown on the right.•If the required key-code is "222222", follow the follow-ing procedure.•Press the

Pagina 27

3.2.2 DISPLAYING A DATAPOINTThe following procedure illustrates how to display the contents of datapoint B012, which is the dis-play brightness index

Pagina 28 - 3.1 CONTROLLER FRONT PANEL

•The display shows the POINT entry line at the bottom ofthe display, as shown on the right.•Press the key until the character "B" app

Pagina 29

3.2.3 DISPLAYING A MODULERefer to Section 3.11 for Keypad function in Module ModeThe navigational sequence would be the following(Refer to Table 3-5)

Pagina 30

3.2.4 CONFIGURE A DATAPOINTThe following procedure illustrates how to alter the contents of datapoint C115 (CONTROL module& Span parameter) from 1

Pagina 31 - 3.2 ENGINEER MODE OVERLAYS

•The existing contents of DATAPOINT C115 are dis-played (shown as 100.000 in this example).•To change the value of C115, first shift the C115 con-tent

Pagina 32

3.2.5 CONFIGURE A MODULEThe navigational sequence would be the following:•Select Module Type (then Module, if there’s more than one Module)•Select Pag

Pagina 33 - 3.2.2 DISPLAYING A DATAPOINT

•If more than one module of the type selected is avail-able, a list of modules appears showing module numberand TAGNAME•Use the buttons t

Pagina 34

3.4 DATABASE MODULES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-273.4.1 AN

Pagina 35 - 3.2.3 DISPLAYING A MODULE

Numeric and Datapoint Data•The current value and an editable value are displayed,as shown in the screen to the right.•Use the buttons to selec

Pagina 36 - 3.2.4 CONFIGURE A DATAPOINT

When the Module Mode configuration is complete, the controller may be returned to the operatormode either by pressing the F1 key to step backwards thr

Pagina 37

CONFIGURE-MODULE MODE MENU ORGANIZATIONSYSTEM ANALOG IN ANALOG OUT DISCRETE IN DISCRETE OUT EXTERNAL CONTROL STATUS PARAMETER TREND TOT

Pagina 38 - 3.2.5 CONFIGURE A MODULE

3.3 KEYPAD ALTERNATIVESThere are six alternative methods other than the faceplate push buttons for accessing and chang-ing database parameters. All

Pagina 39

3.3.1.1 SETUP OF THE HAND HELD CONFIGURERThe Hand Held Configurer is shipped pre-configured to operate with the Controller. If the Config-urer does no

Pagina 40

FIGURE 3-3. FRONT PANEL CONFIGURATION PORT CONNECTIONSMODULAR CONTROLLER QUICK START3-20

Pagina 41

3.3.1.2 DISPLAYING A DATA BASE PARAMETERTo display a data base parameter press "D" and the parameter ID followed by <enter>. The curre

Pagina 42

The "keys" are a special datatype which can be displayed or configured as any other datatype withthe Hand Held Configurer. The "keys&qu

Pagina 43 - 3.3 KEYPAD ALTERNATIVES

2. If F2 is selected, the following menu will appear:F2-DATABASEF3-PROGRAMBased on which selection from this menu is made the following operations wil

Pagina 44

3.3.2 USING A PC TERMINAL EMULATOR3.3.2.1 MICROSOFT WINDOWS HYPERTERMINALThis procedure describes the use of the Microsoft Windows HyperTerminal progr

Pagina 45

READ FIRSTWARNINGINSTRUCTION MANUALSDo not install, maintain, or operate this equipment without reading, understanding andfollowing the proper MicroMo

Pagina 46

7. Select OK to continue.8. The next window is used to configure the PC COM port communications parameters. Thefront port of the 53MC5000 has fixed c

Pagina 47

11. In the Properties window, select the Settings tab as pictured below. Choose the VT100option from the Emulation pull down list. Click OK to conti

Pagina 48

3.4 DATABASE MODULESThe controller’s database is made of many parameters, most of which are not needed for any oneparticular application. The most imp

Pagina 49

3.4.1 ANALOG INPUT MODULESThe analog input modules permit the user to configure the characteristics of each input. The avail-able parameters are shown

Pagina 50

DIGITAL FILTER INDEX :In addition to the input filtering provided in hardware each input may have a first order digital filterapplied to its signal. T

Pagina 51

3.4.2 ANALOG OUTPUT MODULESThe analog output modules permit the user to configure the characteristics of each output. Theavailable parameters are show

Pagina 52 - 3.4 DATABASE MODULES

3.4.3 CONTACT INPUT MODULESThe contact input modules generate logic levels based on the applied voltages or contact conditionon the associated termina

Pagina 53 - 3.4.1 ANALOG INPUT MODULES

3.4.4 CONTACT OUTPUT MODULESThe contact output modules convert a logic level to a hardware contact condition. Output DO2 -DO17 are only active if the

Pagina 54

3.4.5 EXTERNAL INPUT MODULEThe External Input Modules provide the ability to obtain data from other MICRO-DCI instrumentsthrough the Optional Peer to

Pagina 55 - 3.4.2 ANALOG OUTPUT MODULES

3.4.6 CONTROLLER MODULEUp to four CON modules are present in the controller. Compare the model number on the controllerwith the model number breakdown

Pagina 56 - 3.4.3 CONTACT INPUT MODULES

1.0 INTRODUCTION1.1 DESCRIPTIONThis Quick Start Guide provides the information needed to install and wire a 53MC5000 ModularController with a quick an

Pagina 57 - 3.4.4 CONTACT OUTPUT MODULES

The following options and characterization parameters are available in each PID control algorithm.Data point references are for control loop 0. Data p

Pagina 58 - 3.4.5 EXTERNAL INPUT MODULE

SETPOINT TRACKING ENABLE:When the Setpoint Tracking Enable bit STE (L118) is configured to a 1 the controller’s setpoint canbe forced to match Setpoin

Pagina 59 - 3.4.6 CONTROLLER MODULE

ALARM TYPE:The AIX parameter (B335) defines the alarm action interpretation of the two alarm limits. 0 - PA1HIGH (PV > PL1) PA2LOW (PV < P

Pagina 60

3.4.7 STATUS DISPLAY MODULETwo Status Display Modules are present in the controller. Each module provides display and push-button access to eight logi

Pagina 61

STATE:This is the current condition of the individual points (0 or 1).NAME:This is treated as a 10 character name of the point or two 5 character word

Pagina 62

3.4.8 PARAMETER DISPLAY MODULEEight Parameter Display Modules are present in the controller. Each module provides display andpushbutton access to any

Pagina 63 - 3.4.7 STATUS DISPLAY MODULE

3.4.9 TREND MODULESEight Trend Modules are present in the controller. Each module provides storage of the last 80samples of the specified input. The a

Pagina 64

3.4.10 TOTALIZER MODULESEight Totalizer Modules are present in the controller. Each module provides a "totalization" (integra-tion) of the s

Pagina 65

3.4.11 SYSTEM MODULEThe System Module controls the fundamental response of the controller.FUNCTION INDEX:The operational algorithm of the unit is sele

Pagina 66 - 3.4.9 TREND MODULES

SCAN INDEX:This parameter SCAN (B01) determines the frequency of execution for the operation FIX selected.The repetition period equals B01 x 50 mS. Th

Pagina 67 - 3.4.10 TOTALIZER MODULES

1.2.3 FLEXIBLE CONTROL STRATEGIESSection 4.0, FLEXIBLE CONTROL STRATEGIES, includes all the information required to set upand place in operation a 53M

Pagina 68 - 3.4.11 SYSTEM MODULE

Date functions are provided by parameters: Date ParameterDay B260Month B261Year B262As long as power to the unit is maintained, the time and date will

Pagina 69

4.0 FLEXIBLE CONTROL STRATEGY4.1 CS 1 SINGLE LOOP STANDARD PIDIf Model Number 53MC51X1 has been purchased, the controller is shipped from the factory

Pagina 70

4.1.1 CS 1 SINGLE LOOP PID DESCRIPTIONThe "Standard PID" configuration of the Flexible Control Strategy (FCS) is designed to fulfill the re-

Pagina 71 - 4.0 FLEXIBLE CONTROL STRATEGY

4. Configure the PV input signal parameters: Refer to Instruction Bulletin 53MC5000 Section 4.3.1.•Set-up the AI module by entering the span (in Engin

Pagina 72

4.1.3 CS 1 STANDARD PID FCS DISPLAYSThe 53MC5000’s dot matrix display provides unequalled capability for presentation of informationto the user. The d

Pagina 73

4.1.4 CONTROL OPTIONS4.1.4.1 REMOTE SETPOINT1. Configure the RSP input signal parameters:•Set C257 to the span (in Engineering Units) of the RSP range

Pagina 74

•The 53MC5000 is set to accept a 1-5 V RSP signal. If 0-5 V is required, setL419=1.•The 53MC5000 is set to accept a linear PV signal. If square root

Pagina 75 - 4.1.4 CONTROL OPTIONS

FIGURE 4-1. CS 1 FUNCTION BLOCK DIAGRAMMODULAR CONTROLLER QUICK START4-7

Pagina 76

4.2 CS 20 TWO-LOOP STANDARD PIDIf Model Number 53MC52X1 has been purchased, the controller is shipped from the factory loadedwith the FCS CS20 for Two

Pagina 77

2. With the 53MC5000 still in "Suspend mode" (B00=0), load the FDC set-up values for CS20Standard Two Loop PID from the EPROM into controlle

Pagina 78

1.3 MODEL NUMBER BREAKDOWNThe following pages show the detailed breakdown of the 53MC5000B Controller Model NumberMODULAR CONTROLLER QUICK STARTMODNU

Pagina 79

•If HI/LO alarms are required, enter the following:B335=0 (HI/LO alarm index)C103=High alarm setpointC104=Low alarm setpointC105=Alarm deadbandAlarm s

Pagina 80

4.2.3 CS 20 STANDARD PID FCS DISPLAYSThe 53MC5000’s dot matrix display provides unequalled capability for presentation of informationto the user. The

Pagina 81

4.2.4 CONTROL OPTIONS - REMOTE SETPOINTThe 53MC5000 is capable of accepting a setpoint from a remote instrument for loop #1 throughAI2.1. Configure th

Pagina 82

FIGURE 4-2. CS 20 FUNCTION BLOCK DIAGRAMMODULAR CONTROLLER QUICK START4-13

Pagina 83

APPENDIX A.0 - FM APPROVALThe following listed equipment is Factory Mutualapproved as:Nonincendive for use in Class I, Division 2, Group A, B, C &

Pagina 84

APPROVED OPTIONSThe following optional accessories as listed in Chapter 1.0 of the Instruction Manual are suitable foruse in Division 2.•6DI/4DO, Cont

Pagina 85 - APPROVED OPTIONS

APPROVED OPTIONS (cont’d)•Single Channel Analog Input Option.•Multi-Channel Analog I/O Option.•5Bxx Group of mV, Voltage, Current, RTD and Thermocoupl

Pagina 86 - NON-APPROVED OPTIONS

INSTALLATION DIAGRAMSA copy of each of the following interconnection diagrams is included in this Appendix.In Class I, Division 2 installations these

Pagina 87 - CORRECTIVE MAINTENANCE

LITHIUM BATTERY HANDLING PRECAUTIONS Part. No. 167B024U01Manufacturer: Eagle Picher Industries, Inc.Box 130 Bethel RoadSeneca, MO 64865P

Pagina 89

53MC5 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _Base Model NumberControl LoopsOne LoopTwo LoopsFour Loops124Power RequirementsAC (120/240)DC (24)12Functional Requi

Pagina 99

The Company’s policy is one of continuous product improvement and the rightis reserved to modify the information contained herein without notice, or